ArmSoM
← All stories

Building a Robot Control Computer with ArmSoM: Separate AI from Motor Safety

A robot computer may handle perception, planning, networking and control, but those jobs have different timing needs. An ArmSoM SBC or module can host Linux applications while other hardware handles tightly bounded control. Define that split before selecting processors.

ArmSoM Sige5

ArmSoM Sige5

Assign failure behavior as well as tasks

For each function, state what happens if its process stops, input becomes stale or the network disappears. Keep actuator control and emergency behavior tied to a suitable, validated implementation. Test communication between the Linux host and controllers under delay and restart conditions. More compute does not by itself make a control system dependable.

Define failure behavior before performance targets

Specify what happens when a camera stops, the network drops, the process crashes or power falls. Use timestamps and command expiry where appropriate. Test these cases with actuators disabled or on a safe test rig first. A fast object detector does not prove that the complete robot reacts safely.

Measure the complete perception loop

Record capture-to-decision time, missed frames and variation under simultaneous logging and communication. Confirm that model conversion preserves the needed accuracy. Size power and cooling for sustained operation in the final enclosure. Document which functions the NPU performs and which remain on CPU, GPU or another controller.

ArmSoM Sige7s

ArmSoM Sige7s

Match the choice to your requirements

Requirement or situation

What to evaluate

Decision detail

Application computer

Perception, UI and networking

Validate load and recovery.

Actuator controller

Timing and bounded commands

Define loss-of-command behavior.

System design

Power, emergency response and testing

Evaluate independently of AI accuracy.

Example design

Put robot interfaces into a latency and safety budget

A mobile robot might use a Linux board for perception and planning while a separate controller handles motor timing and stop behavior. Define camera bandwidth, sensor updates, command deadlines and recovery after communication loss. Choose the computer from that complete workload. An integrated NPU is relevant only when the intended model and input pipeline work reliably within the system’s timing budget.

Hardware and documentation

Sige5 · RK3576

RK3576, four Cortex-A72 and four Cortex-A53 cores, 6 TOPS NPU, dual Gigabit Ethernet and M.2 PCIe 2.1 x1.

Hardware documentation · Product details

Sige7s · RK3588S

RK3588S, 6 TOPS NPU, Gigabit Ethernet and removable eMMC. Dimensions: 85 × 56 × 17 mm. Disconnect power before replacing eMMC.

Hardware documentation · Product details

Frequently asked questions

Is an NPU required for every robot?

No. The perception workload and software determine whether acceleration is useful.